CONVERSION TABLES

To Different Bases

Desired Basis >
Given Basis v

As Received

Air Dried

Dry

Dry, ash free

Dry, mineral matter free

As Received   100-Mad
100-Mar
100
100-Mar
100
100-(Mar+Aar)
100
100-(Mar+MMar)
Air Dried 100-Mar
100-Mad
  100
100-Mad
100
100-(Mad+Aad)
100
100-(Mad+MMad)
Dry 100-Mar
100
100-Mad
100
  100
100-Ad
100
100-MMd
Dry, ash free 100-(Mar+Aar)
100
100-(Mad+Aad)
100
100-Ad
100
  100-Ad
100-MMd
Dry, mineral matter free

100-(Mar+MMar)
100
100-(Mad+MMad)
100
100-MMd
100
100-MMd
100-Ad
 

Definition of Variables
M = moisture (%)
A = ash (%)
MM = mineral matter (%)

Definition of Subscripts
ar = as received basis
ad = air dried basis
d = dry basis

Specific Energy Conversions
For conversions between units:

1 Btu/lb = 0.002326 MJ/kg
1 kcal/kg = 0.0041868 MJ/kg
1 Metric Ton (tonne) = 1.10231 short tons

The difference between net and gross as received (NAR v/s GAR) specific energy values is the latent heat of the water vapour which lowers the effective calorific value in the boiler. To convert from GAR to NAR for bituminous coals subtract approximately:

1.09 MJ/kg
260 kcal/kg
470 Btu/lb